首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   66篇
  免费   2篇
化学   56篇
晶体学   1篇
力学   1篇
数学   3篇
物理学   7篇
  2021年   2篇
  2020年   4篇
  2019年   1篇
  2018年   1篇
  2017年   1篇
  2016年   3篇
  2015年   3篇
  2014年   2篇
  2013年   8篇
  2012年   4篇
  2011年   6篇
  2010年   4篇
  2009年   4篇
  2008年   2篇
  2006年   2篇
  2005年   5篇
  2004年   3篇
  2003年   4篇
  2002年   4篇
  1994年   1篇
  1977年   1篇
  1975年   1篇
  1965年   1篇
  1963年   1篇
排序方式: 共有68条查询结果,搜索用时 15 毫秒
1.
The refractive indices (n) of eight standard oils from Physikalisch Technische Bundesanstalt, Germany were determined with an accuracy of ±1×10−4 by using Abbe Refractometer. The measurements were performed at temperature 20°C in the spectral range 0.4–0.7 μm. The experimental data were fitted to the simple Cauchy dispersion formula and the results were found to be consistent within the limits of experimental error. In all cases, the refractive index decreased monotonically with increasing wavelength. The refractive indices (n) of these oils have been measured as a function of the temperature t (20°C up to 50°C) at λ=0.589 μm and were found to have linear temperature dependencies. The refractive indices of the studied oils and the uncertainty in their values are calculated at λ=0.589. The Lorentz–Lorenz (L–L) formula has been tested and it was found to be valid with a maximum deviation of 0.4% and was used to calculate the molecular polarizability θ.  相似文献   
2.
A combined interference and diffraction pattern, in the form of equidistant interference fringes, resulting from illuminating a vertical metallic wire by a laser beam is analyzed to measure the diameter of four standard wires. The diameters range from 170 to 450 μm. It is found that the error in the diameter measurements increases for small metallic wires and for small distances between the wire and the screen due to scattering effects. The intensity of the incident laser beam was controlled by a pair of sheet polaroids to minimize the scattered radiation. The used technique is highly sensitive, but requires controlled environmental conditions and absence of vibration effects. The expanded uncertainty for k=2 is calculated and found to decrease from U(D)=±1.45 μm for the wire of nominal diameter 170 μm to ±0.57 μm for the diameter 450 μm.  相似文献   
3.
[reaction: see text] Allylically oxygenated vinyl alpha-triphenylstannanes such as 22 can be readily converted into vinyl iodides and thereafter stereodefined trisubstituted alkenes with retention of configuration.  相似文献   
4.
A simple method has been developed for the pre-column derivatisation of low molecular weight primary and secondary amines and carboxylic acids using quaternary nitrogen compounds to enhance their detection by liquid chromatography/electrospray ionisation mass spectrometry (LC/ESI-MS). The synthesis of seven novel quaternary nitrogen reagents is described. The derivatives are designed to be relatively small molecules to avoid some of the steric hindrance problems that may be associated with larger derivatisation reagents. The compounds have amine and carboxylic acid functional groups with which to derivatise carboxylic acids and amines, respectively. Two of the compounds contain a bromine atom in order to assess the advantages of a bromine isotope pattern in the mass spectra. This acts as a simple marker for derivatisation and enables data processing by cluster analysis.Activation of the carboxylic acid group was achieved by the use of either 1-chloro-4-methylpyridinium iodide (CMPI) or the more reactive 1-fluoro-4-methylpyridinium p-toluenesulphonate (FMP).1 Using both of these active reagents, the degree of nucleophilic substitution was investigated for the derivatisation of a variety of small molecules. Whilst giving some increase in the ESI-MS response for the derivatised compounds, the FMP itself acted as a derivatising reagent in a competing reaction. In the light of this finding, FMP was reacted with the test compounds separately and gave positive results as a derivatising reagent. Detection of the 'pre-charged' derivatives of amines and carboxylic acids by LC/ESI-MS was investigated with respect to their ESI response and chromatography.  相似文献   
5.
[structure: see text] The synthesis of two truncated bryostatin analogues 2 and 3 is described. High-field NMR measurements on the C-ring analogue 3 in C(2)H(3)CN containing 25% (2)H(2)O have shown that it binds to the CRD2 of human PKC-alpha at virtually the same position as phorbol-13-acetate (PA) and bryostatin 1 (1). NMR titration studies have also revealed that 3 binds to the CRD2 with a potency similar in magnitude to PA but much less potently than 1.  相似文献   
6.
[reaction: see text] The "Southern Hemisphere" intermediate 2, used by Masamune and co-workers for their asymmetric total synthesis of bryostatin 7 (1), has been synthesized from (E)-1,4-hexadiene (11) by a 24-step pathway that has a longest linear sequence of only 20 steps. This is the shortest synthesis of 2 so far recorded, and moreover, it is fully stereocontrolled.  相似文献   
7.
8.
A computational study of inclusion complexes of 2-methyl-βCD with Doxycycline tautomeric (enol and keto form) has been performed with several combinations of ONIOM hybrid calculations. The reliability of the ONIOM2 calculations at the integrated level, ONIOM2 (M05-2X/6-31G(d): M05-2X/3-21G*), ONIOM2 (M05-2X/6-31G(d):HF/3-21G*), ONIOM2 (B3LYP/6-31G(d):HF/3-21G*), ONIOM2 (B3LYP/6-31G(d):B3LYP/3-21G*) and ONIOM2 (B3PW91/6-31G(d):B3PW91/3-21G*) was examined. Their complexation, binding, deformation and stabilization energies, and geometrical data were compared with those of the target geometry structure optimized at the M05-2X/6-31G(d) level of theory. Mixed combinations ONIOM2 (M05-2X 6-31G(d):HF 3-21G*) and ONIOM2 (B3LYP 6-31G(d):HF 3-21G*) reproduces nearly the target geometry structure and provides realistic energetic results at a relatively low computational cost.  相似文献   
9.
10.
Since the advent of the Guide to the Expression of Uncertainty in Measurement (GUM) founding the principles of uncertainty evaluation, numerous projects have been carried out to develop alternative practical methods when it is impossible to model technical or economical aspects of the measurement process. These methods can use all the experimental data available to the laboratories, such as repeatability, reproducibility, quality-control charts, etc. The studies presented in this paper compare the results obtained by the modelling method from GUM with the uncertainties found by applying alternative methods. They show two examples, one in the field of environmental monitoring, the other in the biomedical field, based on the exploitation of PT schemes results. Presented at BERM-11, October 2007, Tsukuba, Japan.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号